160 research outputs found

    A Manufacturer Design Kit for Multi-Chip Power Module Layout Synthesis

    Get PDF
    The development of Multi-Chip Power Modules (MCPMs) has been a key factor in recent advancements in power electronics technologies. MCPMs achieve higher power density by combining multiple power semiconductor devices into one package. The work detailed in this thesis is part of an ongoing project to develop a computer-aided design software tool known as PowerSynth for MCPM layout synthesis and optimization. This thesis focuses on the definition and design of a Manufacturer Design Kit (MDK) for PowerSynth, which enables the designer to design an MCPM for a manufacturer’s fabrication process. The MDK is comprised of a layer stack and technology library, design rule checking (DRC), and layout versus schematic checking. File formats have been defined for layer stack and design rule input, and import functions have been written and integrated with the existing user interface and data structures to allow PowerSynth to accept these file formats as a form of input. Finally, an exhaustive DRC function has been implemented to allow the designer to verify that a synthesized layout meets all design rules before committing the design to manufacturing. This function was validated by running DRC on an example layout solution using two different sets of design rules

    Mediators of Treatment Effect in the Back In Action Trial:Using Latent Growth Modeling to Take Change Over Time Into Account

    Get PDF
    Objectives: To test whether change in fear-avoidance beliefs was a mediator of the effect of treatment on disability outcome, and to test an analytical approach, latent growth modeling, not often applied to mediation analysis. Methods: Secondary analysis was carried out on a randomized controlled trial designed to compare an intervention addressing fear-avoidance beliefs (n=119) with treatment as usual (n=121) for patients with low back pain, which found the intervention to be effective. Latent growth modelling was used to perform a mediation analysis on the trial data to assess the role of change in fear-avoidance beliefs on disability outcome. The product of coefficients with bias-corrected bootstrapped confidence intervals was used to calculate the mediating effect. Results: A statistically significant mediating effect of fear-avoidance beliefs on the effect of treatment on disability outcome was found (standardized indirect effect −0.35; bias-corrected 95% CI, −0.47 to −0.24). Poor fit of the model to the data suggested that other factors not accounted for in this model are likely to be part of the same mediating pathway. Discussion: Fear-avoidance beliefs were found to mediate the effect of treatment on disability outcome. Measurement of all potential mediator variables in future studies would help to more strongly identify which factors explain observed treatment effects. Latent growth modelling was found to be a useful technique to apply to studies of treatment mediation, suggesting that future studies could use this approach

    The Good Childhood Report 2014

    Get PDF
    The Good Childhood Report 2014 is the third in a series of annual reports published by The Children's Society about how children in the UK feel about their lives. The first part of the report presents an updated picture of overall levels of subjective well-being in the UK. The second part of the report looks at new evidence on four different factors that are associated with children's subjective well-being: children's activities and behaviours, material conditions - deprivation, relative wealth and changes over time, parental subjective well-being and mental health, and parenting behaviours

    The Good Childhood Report 2015

    Get PDF
    This is the fourth annual Good Childhood Report. It is based on The Children's Society's ongoing research on children's subjective well-being, undertaken in collaboration with the University of York, which is the most extensive programme of national research on children's subjective well-being globally. The purpose of this series of reports is to provide the best available up-to-date information about the perspectives of children in the UK on their lives and well-being

    Predicting spontaneous clearance of acute hepatitis C virus in a large cohort of HIV-1-infected men

    Get PDF
    <b>Objective</b> An epidemic of acute hepatitis C virus (HCV) infection in HIV-positive men-who-have-sex-with-men (MSM) is emerging in Europe, Australia and the USA. The aim of this study was to characterise the natural history of primary HCV in this setting and to assess host and viral factors which predict spontaneous clearance.<p></p> <b>Methods</b> This prospective longitudinal cohort study was carried out in 112 HIV-positive patients who were followed in a single centre (the St Mary's Acute HCV Cohort). Plasma and peripheral blood mononuclear cells (PBMCs) were obtained at monthly intervals for 3 months and at 3-monthly intervals thereafter for a median of 45 months (IQR=29–69 months). The primary end point was spontaneous clearance of HCV. Cox regression was used to assess the impact of clinical and virological variables on outcome, including liver function, CD4 count, rate of HCV RNA decline, T cell response and clonal sequence evolution within the HCV E2 envelope gene.<p></p> <b>Results</b> 15% of patients cleared HCV spontaneously, while 85% progressed towards chronicity. The latter group included a significant proportion of ‘fluctuating’ progressors (37.5%), in whom a fall followed by a rise (>1 log10) in viraemia was observed. This was associated with superinfection with new HCV strains and partially effective T cell responses. Spontaneous clearance was strongly associated with a 2.2 log10 viral load drop within 100 days of infection (HR=1.78; p<0.0001), elevated bilirubin (≥40 μmol/l; HR=5.04; p=0.006), elevated alanine aminotransferase (ALT; ≥1000 IU/ml; HR=2.62; p=0.048) and baseline CD4 count ≥650×106/l (HR=2.66; p=0.045), and only occurred in patients with genotype 1 infection. Evolution to spontaneous clearance occurred in patients with low viral diversity in the presence of an early multispecific T cell response.<p></p> <b>Conclusions</b> Spontaneous clearance of acute HCV in HIV-positive men can be predicted by a rapid decline in viral load, high CD4 count, elevated bilirubin and ALT, and is associated with low viral diversity and strong T cell responses

    A clinical observational analysis of aerosol emissions from dental procedures

    Get PDF
    Aerosol generating procedures (AGPs) are defined as any procedure releasing airborne particles <5 μm in size from the respiratory tract. There remains uncertainty about which dental procedures constitute AGPs. We quantified the aerosol number concentration generated during a range of periodontal, oral surgery and orthodontic procedures using an aerodynamic particle sizer, which measures aerosol number concentrations and size distribution across the 0.5–20 μm diameter size range. Measurements were conducted in an environment with a sufficiently low background to detect a patient’s cough, enabling confident identification of aerosol. Phantom head control experiments for each procedure were performed under the same conditions as a comparison. Where aerosol was detected during a patient procedure, we assessed whether the size distribution could be explained by the non-salivary contaminated instrument source in the respective phantom head control procedure using a two-sided unpaired t-test (comparing the mode widths (log(σ)) and peak positions (D(P,C))). The aerosol size distribution provided a robust fingerprint of aerosol emission from a source. 41 patients underwent fifteen different dental procedures. For nine procedures, no aerosol was detected above background. Where aerosol was detected, the percentage of procedure time that aerosol was observed above background ranged from 12.7% for ultrasonic scaling, to 42.9% for 3-in-1 air + water syringe. For ultrasonic scaling, 3-in-1 syringe use and surgical drilling, the aerosol size distribution matched the non-salivary contaminated instrument source, with no unexplained aerosol. High and slow speed drilling produced aerosol from patient procedures with different size distributions to those measured from the phantom head controls (mode widths log(σ)) and peaks (D(P,C), p< 0.002) and, therefore, may pose a greater risk of salivary contamination. This study provides evidence for sources of aerosol generation during common dental procedures, enabling more informed evaluation of risk and appropriate mitigation strategies

    High-definition colonoscopy versus Endocuff versus EndoRings versus Full-Spectrum Endoscopy for adenoma detection at colonoscopy: a multicenter randomized trial

    Get PDF
    Background Devices used to improve polyp detection during colonoscopy have seldom been compared with each other. Methods We performed a 3-center prospective randomized trial comparing high-definition (HD) forward-viewing colonoscopy alone to HD with Endocuff to HD with EndoRings to the Full Spectrum Endoscopy (FUSE) system. Patients were age ≥50 years and had routine indications and intact colons. The study colonoscopists were all proven high-level detectors. The primary endpoint was adenomas per colonoscopy (APC) Results Among 1,188 patients who completed the study, APC with Endocuff (APC Mean ± SD 1.82 ± 2.58), EndoRings (1.55 ± 2.42), and standard HD colonoscopy (1.53 ± 2.33) were all higher than FUSE (1.30 ± 1.96,) (p<0.001 for APC). Endocuff was higher than standard HD colonoscopy for APC (p=0.014) . Mean cecal insertion times with FUSE (468 ± 311 seconds) and EndoRings (403 ± 263 seconds) were both longer than with Endocuff (354 ± 216 seconds) (p=0.006 and 0.018, respectively). Conclusions For high-level detectors at colonoscopy, forward-viewing HD instruments dominate the FUSE system, indicating that for these examiners image resolution trumps angle of view. Further, Endocuff is a dominant strategy over EndoRings and no mucosal exposure device on a forward-viewing HD colonoscope
    corecore